Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Pairs |
28 |
7x36 |
TC - Tinned Copper |
5 |
Material |
Material Trade Name |
Nominal Wall Thickness |
FPE - Foamed Polyethylene |
Datalene® |
0.015 in |
Number |
Color |
1 |
White/Blue & Blue/White |
2 |
White/Orange & Orange/White |
3 |
White/Green & Green/White |
4 |
White/Brown & Brown/White |
5 |
White/Gray & Gray/White |
Type |
Layer |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire AWG |
Drainwire Construction n x D |
Tape |
1 |
Aluminum/Polyester |
Beldfoil® |
100 % |
TC - Tinned Copper |
28 |
7x36 mm |
Braid |
2 |
TC - Tinned Copper |
|
65 % |
|
|
|
Material |
Nominal Diameter |
Nominal Wall Thickness |
PVC - Polyvinyl Chloride |
0.288 in |
0.035 in |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Outer Shield DCR |
65 Ohm/1000ft |
4.2 Ohm/1000ft |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
11 pF/ft |
20 pF/ft |
Nominal Characteristic Impedance |
120 Ohm |
Max. Delay Skew |
Nominal Velocity of Propagation (VP) [%] |
78 ns/100m |
78 % |
Max. Recommended Current [A] |
0.9 Amps per conductor @ 25°C A |
UL Description |
UL Voltage Rating |
UL AWM Style 2919 |
30 V RMS (UL AWM Style 2919) |
CL2 |
150 V RMS (CL2) |
Temperature Range
UL Temp Rating: |
80°C (UL AWM Style 2919) |
Operating Temp Range: |
-30°C To +80°C |
Mechanical Characteristics
Bulk Cable Weight: |
36 lbs/1000ft |
Min Bend Radius/Minor Axis: |
3 in |
Standards
NEC/(UL) Specification: |
CL2 |
UL AWM Style: |
2919 (30 V 80°C) |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2003/96/EC (BFR): |
Yes |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
EU RoHS Compliance Date (yyyy-mm-dd): |
2004-01-01 |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flammability, LS0H, Toxicity Testing
UL Flammability: |
UL1685 UL Loading |
ISO/IEC Flammability: |
IEC 60332-1-2 |
UL voltage rating: |
30 V RMS (UL AWM Style 2919) |
Plenum/Non-Plenum